Adjusted cancel_print. Added pause, resume, m600.

This commit is contained in:
Bassam Husain
2022-12-25 22:14:12 -05:00
parent 72de539b78
commit d00fbc689b

View File

@@ -14,14 +14,23 @@ gcode:
G92 E0.0 ; reset extruder
G1 Z2.0 ; move nozzle to prevent scratch
# [gcode_macro CANCEL_PRINT]
# description: Cancel the actual running print
# rename_existing: CANCEL_PRINT_BASE
# gcode:
# TURN_OFF_HEATERS
# M107 ; turn off fan
# CANCEL_PRINT_BASE
[gcode_macro CANCEL_PRINT]
description: Cancel the actual running print
rename_existing: CANCEL_PRINT_BASE
rename_existing: BASE_CANCEL_PRINT
gcode:
TURN_OFF_HEATERS
M107 ; turn off fan
CANCEL_PRINT_BASE
SET_IDLE_TIMEOUT TIMEOUT={printer.configfile.settings.idle_timeout.timeout} ; set timeout back to configured value
CLEAR_PAUSE
SDCARD_RESET_FILE
PRINT_END
BASE_CANCEL_PRINT
[gcode_macro PRINT_START]
# Use PRINT_START for the slicer starting script - please customize for your slicer of choice
#gcode:
@@ -206,3 +215,63 @@ gcode:
G1 E10 F300 ; extrude a little to soften tip
G1 E-40 F1800 ; retract some, but not too much or it will jam
M82 ; set extruder to absolute
[gcode_macro M600]
gcode:
#LCDRGB R=0 G=1 B=0 ; Turn LCD green
PAUSE ; Pause
[gcode_macro PAUSE]
rename_existing: BASE_PAUSE
gcode:
# Parameters
{% set z = params.Z|default(10)|int %} ; z hop amount
{% if printer['pause_resume'].is_paused|int == 0 %}
SET_GCODE_VARIABLE MACRO=RESUME VARIABLE=zhop VALUE={z} ; set z hop variable for reference in resume macro
SET_GCODE_VARIABLE MACRO=RESUME VARIABLE=etemp VALUE={printer['extruder'].target} ; set hotend temp variable for reference in resume macro
# SET_FILAMENT_SENSOR SENSOR=filament_sensor ENABLE=0 ; disable filament sensor
SAVE_GCODE_STATE NAME=PAUSE ; save current print position for resume
BASE_PAUSE ; pause print
{% if (printer.gcode_move.position.z + z) < printer.toolhead.axis_maximum.z %} ; check that zhop doesn't exceed z max
G91 ; relative positioning
G1 Z{z} F900 ; raise Z up by z hop amount
{% else %}
{ action_respond_info("Pause zhop exceeds maximum Z height.") } ; if z max is exceeded, show message and set zhop value for resume to 0
SET_GCODE_VARIABLE MACRO=RESUME VARIABLE=zhop VALUE=0
{% endif %}
G90 ; absolute positioning
G1 X{printer.toolhead.axis_maximum.x/2} Y{printer.toolhead.axis_minimum.y+5} F6000 ; park toolhead at front center
SAVE_GCODE_STATE NAME=PAUSEPARK ; save parked position in case toolhead is moved during the pause (otherwise the return zhop can error)
M104 S0 ; turn off hotend
SET_IDLE_TIMEOUT TIMEOUT=43200 ; set timeout to 12 hours
{% endif %}
[gcode_macro RESUME]
rename_existing: BASE_RESUME
variable_zhop: 0
variable_etemp: 0
gcode:
# Parameters
{% set e = params.E|default(2.5)|int %} ; hotend prime amount (in mm)
{% if printer['pause_resume'].is_paused|int == 1 %}
# SET_FILAMENT_SENSOR SENSOR=filament_sensor ENABLE=1 ; enable filament sensor
#INITIAL_RGB ; reset LCD color
SET_IDLE_TIMEOUT TIMEOUT={printer.configfile.settings.idle_timeout.timeout} ; set timeout back to configured value
{% if etemp > 0 %}
M109 S{etemp|int} ; wait for hotend to heat back up
{% endif %}
RESTORE_GCODE_STATE NAME=PAUSEPARK MOVE=1 MOVE_SPEED=100 ; go back to parked position in case toolhead was moved during pause (otherwise the return zhop can error)
G91 ; relative positioning
M83 ; relative extruder positioning
{% if printer[printer.toolhead.extruder].temperature >= printer.configfile.settings.extruder.min_extrude_temp %}
G1 Z{zhop * -1} E{e} F900 ; prime nozzle by E, lower Z back down
{% else %}
G1 Z{zhop * -1} F900 ; lower Z back down without priming (just in case we are testing the macro with cold hotend)
{% endif %}
RESTORE_GCODE_STATE NAME=PAUSE MOVE=1 MOVE_SPEED=60 ; restore position
BASE_RESUME ; resume print
{% endif %}