Files
school_archives/OSU SARL/Control Board Firmware/Dechorionator/Driver Board Revision 0.1/User Manual.lyx
Corwin Perren b300c76103 Added old firmware and pcb design files
These are all design documents that I thought I had lost. It's may make
me cringe, but it's still cool to use it to see how far I've come.
2016-05-12 20:04:43 -07:00

529 lines
8.3 KiB
Plaintext

#LyX 2.0 created this file. For more info see http://www.lyx.org/
\lyxformat 413
\begin_document
\begin_header
\textclass article
\use_default_options true
\maintain_unincluded_children false
\language english
\language_package default
\inputencoding auto
\fontencoding global
\font_roman default
\font_sans default
\font_typewriter default
\font_default_family default
\use_non_tex_fonts false
\font_sc false
\font_osf false
\font_sf_scale 100
\font_tt_scale 100
\graphics default
\default_output_format default
\output_sync 0
\bibtex_command default
\index_command default
\paperfontsize default
\spacing single
\use_hyperref false
\papersize default
\use_geometry false
\use_amsmath 1
\use_esint 1
\use_mhchem 1
\use_mathdots 1
\cite_engine basic
\use_bibtopic false
\use_indices false
\paperorientation portrait
\suppress_date true
\use_refstyle 1
\index Index
\shortcut idx
\color #008000
\end_index
\secnumdepth 3
\tocdepth 3
\paragraph_separation indent
\paragraph_indentation default
\quotes_language english
\papercolumns 1
\papersides 1
\paperpagestyle default
\tracking_changes false
\output_changes false
\html_math_output 0
\html_css_as_file 0
\html_be_strict false
\end_header
\begin_body
\begin_layout Title
\series bold
Dechorionation Table User Manual - Draft
\end_layout
\begin_layout Standard
\align center
Sinhubber Aquatic Research Laboratory
\end_layout
\begin_layout Standard
\align center
Oregon State University
\end_layout
\begin_layout Standard
\align center
Corwin Perren
\end_layout
\begin_layout Standard
\begin_inset Newpage pagebreak
\end_inset
\end_layout
\begin_layout Part*
Firmware Rev 1.0
\end_layout
\begin_layout Section*
Using the Dechorionator
\end_layout
\begin_layout Enumerate
Turn on the Dechorionator using the power switch located on the rear of
the unit.
\end_layout
\begin_layout Enumerate
Wait until the device has finished powering up and shows the program selection
screen.
\end_layout
\begin_layout Enumerate
Rotate the selection knob until the desired program is shown.
\end_layout
\begin_layout Enumerate
Press the green start button to begin the program.
\end_layout
\begin_layout Enumerate
To skip a particular cycle in a program, press the start button.
\end_layout
\begin_layout Enumerate
Press the stop button at any time to immediately end the currently running
program and return to the selection screen.
\end_layout
\begin_layout Section*
Changing Settings
\end_layout
\begin_layout Enumerate
Rotate the selection knob until the program containing the settings you
would like to modify is shown.
\end_layout
\begin_layout Enumerate
Press the knob to enter the settings editor for that program.
\end_layout
\begin_layout Enumerate
Rotate the selection knob until the setting you would like to change is
shown.
\end_layout
\begin_layout Enumerate
Press the knob to enter the setting's edit screen.
\end_layout
\begin_layout Enumerate
Rotate the selection knob until the desired value is displayed.
\end_layout
\begin_layout Enumerate
Press the knob to save the new value and return to the settings selection
screen.
\end_layout
\begin_layout Enumerate
Repeat for any other settings you would like to change for the selected
program.
\end_layout
\begin_layout Enumerate
Saving Settings
\end_layout
\begin_deeper
\begin_layout Enumerate
Save settings temporarily (Does not persist through reboots).
\end_layout
\begin_deeper
\begin_layout Enumerate
Return to the settings selection screen.
\end_layout
\begin_layout Enumerate
Press the stop button or wait for a few seconds for it to timeout.
\end_layout
\begin_layout Enumerate
You will be returned to the main program selection screen and any modified
settings will be applied until a reboot.
\end_layout
\end_deeper
\begin_layout Enumerate
Save settings permanently (Settings will persist through reboots).
\end_layout
\begin_deeper
\begin_layout Enumerate
Return to the settings selection screen.
\end_layout
\begin_layout Enumerate
Press the start button.
\end_layout
\begin_layout Enumerate
\begin_inset Quotes eld
\end_inset
Settings Saved Sucessfully
\begin_inset Quotes erd
\end_inset
should display breifly before returning to the main program selection screen.
\end_layout
\end_deeper
\end_deeper
\begin_layout Section*
Program Cycle Information and Settings Defaults
\end_layout
\begin_layout Standard
\shape italic
Note that cycles are in order and motor settings apply to all cycles for
a given program.
\end_layout
\begin_layout Subsubsection*
Standard Dechorionation Cycles
\end_layout
\begin_layout Enumerate
Pronase Cycle 1
\end_layout
\begin_deeper
\begin_layout Enumerate
Pronase Cycle 1 - Minutes :
\series bold
6
\end_layout
\begin_layout Enumerate
Pronase Cycle 1 - Seconds :
\series bold
30
\end_layout
\end_deeper
\begin_layout Enumerate
Rinse Cycle
\end_layout
\begin_deeper
\begin_layout Enumerate
Rinse Cycle - Minutes :
\series bold
1
\end_layout
\begin_layout Enumerate
Rinse Cycle - Seconds :
\series bold
0
\end_layout
\end_deeper
\begin_layout Enumerate
Pronase Cycle 2
\end_layout
\begin_deeper
\begin_layout Enumerate
Pronase Cycle 2 - Minutes :
\series bold
10
\end_layout
\begin_layout Enumerate
Pronase Cycle 2 - Seconds :
\series bold
0
\end_layout
\end_deeper
\begin_layout Enumerate
Motor Settings
\end_layout
\begin_deeper
\begin_layout Enumerate
Rotation Speed - Percentage :
\series bold
85
\end_layout
\begin_layout Enumerate
Rotation Ramping Percentage :
\series bold
85
\end_layout
\begin_layout Enumerate
Pump Speed :
\series bold
50
\end_layout
\begin_layout Enumerate
Pump ramp :
\series bold
85
\end_layout
\end_deeper
\begin_layout Subsubsection*
24 Hour Dechorionation Cycles
\end_layout
\begin_layout Enumerate
Pronase Cycle 1
\end_layout
\begin_deeper
\begin_layout Enumerate
Pronase Cycle 1 - Minutes :
\series bold
3
\end_layout
\begin_layout Enumerate
Pronase Cycle 1 - Seconds :
\series bold
0
\end_layout
\end_deeper
\begin_layout Enumerate
Rinse Cycle
\end_layout
\begin_deeper
\begin_layout Enumerate
Rinse Cycle - Minutes :
\series bold
1
\end_layout
\begin_layout Enumerate
Rinse Cycle - Seconds :
\series bold
0
\end_layout
\end_deeper
\begin_layout Enumerate
Pronase Cycle 2
\end_layout
\begin_deeper
\begin_layout Enumerate
Pronase Cycle 2 - Minutes :
\series bold
10
\end_layout
\begin_layout Enumerate
Pronase Cycle 2 - Seconds :
\series bold
0
\end_layout
\end_deeper
\begin_layout Enumerate
Motor Settings
\end_layout
\begin_deeper
\begin_layout Enumerate
Rotation Speed - Percentage :
\series bold
85
\end_layout
\begin_layout Enumerate
Rotation Ramping Percentage :
\series bold
85
\end_layout
\begin_layout Enumerate
Pump Speed :
\series bold
50
\end_layout
\begin_layout Enumerate
Pump ramp :
\series bold
85
\end_layout
\end_deeper
\begin_layout Subsubsection*
6 Hour HPF Dechorionation Cycles
\end_layout
\begin_layout Enumerate
Pronase Cycle 1
\end_layout
\begin_deeper
\begin_layout Enumerate
Pronase Cycle 1 - Minutes :
\series bold
6
\end_layout
\begin_layout Enumerate
Pronase Cycle 1 - Seconds :
\series bold
30
\end_layout
\end_deeper
\begin_layout Enumerate
Rinse Cycle
\end_layout
\begin_deeper
\begin_layout Enumerate
Rinse Cycle - Minutes :
\series bold
1
\end_layout
\begin_layout Enumerate
Rinse Cycle - Seconds :
\series bold
0
\end_layout
\end_deeper
\begin_layout Enumerate
Pronase Cycle 2
\end_layout
\begin_deeper
\begin_layout Enumerate
Pronase Cycle 2 - Minutes :
\series bold
10
\end_layout
\begin_layout Enumerate
Pronase Cycle 2 - Seconds :
\series bold
0
\end_layout
\end_deeper
\begin_layout Enumerate
Motor Settings
\end_layout
\begin_deeper
\begin_layout Enumerate
Rotation Speed - Percentage :
\series bold
85
\end_layout
\begin_layout Enumerate
Rotation Ramping Percentage :
\series bold
85
\end_layout
\begin_layout Enumerate
Pump Speed :
\series bold
50
\end_layout
\begin_layout Enumerate
Pump ramp :
\series bold
85
\end_layout
\end_deeper
\begin_layout Subsubsection*
Rinse Cycle
\end_layout
\begin_layout Enumerate
Rinse Cycle
\end_layout
\begin_deeper
\begin_layout Enumerate
Rinse Cycle - Minutes :
\series bold
1
\end_layout
\begin_layout Enumerate
Rinse Cycle - Seconds :
\series bold
0
\end_layout
\end_deeper
\begin_layout Enumerate
Motor Settings
\end_layout
\begin_deeper
\begin_layout Enumerate
Pump Speed :
\series bold
50
\end_layout
\begin_layout Enumerate
Pump ramp :
\series bold
85
\end_layout
\end_deeper
\end_body