From a71ba1569a72d12f70c2672bb8dc829c50374fba Mon Sep 17 00:00:00 2001 From: Bassam Husain Date: Thu, 13 Apr 2023 17:31:24 -0400 Subject: [PATCH] Pulling in from master. --- cfgs/misc-macros.cfg | 3 ++- 1 file changed, 2 insertions(+), 1 deletion(-) diff --git a/cfgs/misc-macros.cfg b/cfgs/misc-macros.cfg index 70fc90b..73c7528 100644 --- a/cfgs/misc-macros.cfg +++ b/cfgs/misc-macros.cfg @@ -123,12 +123,13 @@ gcode: # Set safe speeds {% set maxVelocity = printer.configfile.settings.printer.max_velocity|default(200)|int %} - {% set maxVelocityAdjusted = (0.95 * maxVelocity * 60)|int %} + {% set maxVelocityAdjusted = (0.90 * maxVelocity * 60)|int %} ADJUST_FILAMENT_SENSOR_STATUS ENABLE=1 G90 M140 S{bedtemp} ; set & don't wait for bed temp + M104 S150 ; set & don't wait for hotend temp G28 X Y M190 S{bedtemp} ; set & wait for bed temp