Merging filament sensor related code.

This commit is contained in:
Bassam Husain
2023-03-12 01:32:40 -05:00
parent 3c84c049c8
commit 69a5cbc45c
2 changed files with 35 additions and 10 deletions

View File

@@ -14,10 +14,28 @@ path: /home/pi/printer_data/gcodes
[pause_resume] [pause_resume]
[display_status] [display_status]
[delayed_gcode DISABLEFILAMENTSENSOR]
initial_duration: 1
gcode:
SET_FILAMENT_SENSOR SENSOR=filament_sensor ENABLE=0
[gcode_macro _globals] [gcode_macro _globals]
variable_pre_purge_prime_length: 1.4 variable_pre_purge_prime_length: 1.4
variable_filament_sensor_enabled: 0 # NOTE Enable(1) or disable(0) the filament sensor, if one is connected
gcode: gcode:
SET_GCODE_VARIABLE MACRO=_globals VARIABLE=pre_purge_prime_length VALUE={ variable_pre_purge_prime_length } SET_GCODE_VARIABLE MACRO=_globals VARIABLE=pre_purge_prime_length VALUE={ variable_pre_purge_prime_length }
SET_GCODE_VARIABLE MACRO=_globals VARIABLE=filament_sensor_enabled VALUE={ variable_filament_sensor_enabled }
[gcode_macro ADJUST_FILAMENT_SENSOR_STATUS]
gcode:
# Parameters
{% set NEWSTATUS = params.ENABLE|default(-1)|int %}
{% set FILAMENT_SENSOR_ENABLED=printer["gcode_macro _globals"].filament_sensor_enabled|default(-1)|int %}
{% if FILAMENT_SENSOR_ENABLED == 1 and NEWSTATUS != -1 %}
SET_FILAMENT_SENSOR SENSOR=filament_sensor ENABLE=NEWSTATUS
{% endif %}
[gcode_macro CHECK_PRE_PURGE_PRIME_LENGTH] [gcode_macro CHECK_PRE_PURGE_PRIME_LENGTH]
gcode: gcode:
@@ -72,16 +90,14 @@ gcode:
BASE_CANCEL_PRINT BASE_CANCEL_PRINT
[gcode_macro PRINT_START] [gcode_macro PRINT_START]
# Use PRINT_START for the slicer starting script - please customize for your slicer of choice gcode:
#gcode:
# G28 ; home all axes
# G1 Z20 F3000 ; move nozzle away from bed
gcode:
# Parameters # Parameters
{% set bedtemp = params.BED|int %} {% set bedtemp = params.BED|int %}
{% set hotendtemp = params.HOTEND|int %} {% set hotendtemp = params.HOTEND|int %}
{% set chambertemp = params.CHAMBER|default(0)|int %} {% set chambertemp = params.CHAMBER|default(0)|int %}
ADJUST_FILAMENT_SENSOR_STATUS ENABLE=1
G28 X Y G28 X Y
# <insert your routines here> # <insert your routines here>
M140 S{bedtemp} ; set & don't wait for bed temp M140 S{bedtemp} ; set & don't wait for bed temp
@@ -97,9 +113,9 @@ gcode:
G1 Z20 F3000 ; move nozzle away from bed G1 Z20 F3000 ; move nozzle away from bed
[gcode_macro PRINT_END] [gcode_macro PRINT_END]
# Use PRINT_END for the slicer ending script - please customize for your slicer of choice
gcode: gcode:
BEEP I=2 DUR=30 FREQ=8500 ; NOTE Comment out this line to stop the beeps at the end of a print ADJUST_FILAMENT_SENSOR_STATUS ENABLE=0
BEEP I=2 DUR=30 FREQ=8500 ; NOTE Comment out this line to stop the beeps at the end of a print
{% set PRE_PURGE_PRIME_LENGTH=printer["gcode_macro _globals"].pre_purge_prime_length|default(1.40)|float %} {% set PRE_PURGE_PRIME_LENGTH=printer["gcode_macro _globals"].pre_purge_prime_length|default(1.40)|float %}
M400 ; wait for buffer to clear M400 ; wait for buffer to clear
G92 E0 ; zero the extruder G92 E0 ; zero the extruder
@@ -166,7 +182,7 @@ gcode:
SET_GCODE_VARIABLE MACRO=RESUME VARIABLE=zhop VALUE={z} ; set z hop variable for reference in resume macro SET_GCODE_VARIABLE MACRO=RESUME VARIABLE=zhop VALUE={z} ; set z hop variable for reference in resume macro
SET_GCODE_VARIABLE MACRO=RESUME VARIABLE=etemp VALUE={printer['extruder'].target} ; set hotend temp variable for reference in resume macro SET_GCODE_VARIABLE MACRO=RESUME VARIABLE=etemp VALUE={printer['extruder'].target} ; set hotend temp variable for reference in resume macro
# SET_FILAMENT_SENSOR SENSOR=filament_sensor ENABLE=0 ; disable filament sensor ADJUST_FILAMENT_SENSOR_STATUS ENABLE=0
SAVE_GCODE_STATE NAME=PAUSE ; save current print position for resume SAVE_GCODE_STATE NAME=PAUSE ; save current print position for resume
BASE_PAUSE ; pause print BASE_PAUSE ; pause print
{% if (printer.gcode_move.position.z + z) < printer.toolhead.axis_maximum.z %} ; check that zhop doesn't exceed z max {% if (printer.gcode_move.position.z + z) < printer.toolhead.axis_maximum.z %} ; check that zhop doesn't exceed z max
@@ -192,8 +208,8 @@ gcode:
{% set e = params.E|default(2.5)|int %} ; hotend prime amount (in mm) {% set e = params.E|default(2.5)|int %} ; hotend prime amount (in mm)
{% if printer['pause_resume'].is_paused|int == 1 %} {% if printer['pause_resume'].is_paused|int == 1 %}
# SET_FILAMENT_SENSOR SENSOR=filament_sensor ENABLE=1 ; enable filament sensor ADJUST_FILAMENT_SENSOR_STATUS ENABLE=1
#INITIAL_RGB ; reset LCD color
SET_IDLE_TIMEOUT TIMEOUT={printer.configfile.settings.idle_timeout.timeout} ; set timeout back to configured value SET_IDLE_TIMEOUT TIMEOUT={printer.configfile.settings.idle_timeout.timeout} ; set timeout back to configured value
{% if etemp > 0 %} {% if etemp > 0 %}
M109 S{etemp|int} ; wait for hotend to heat back up M109 S{etemp|int} ; wait for hotend to heat back up

View File

@@ -220,6 +220,15 @@ shutdown_value: 0
pwm: True pwm: True
cycle_time: 0.0005 ; Default beeper tone in kHz. 1 / 0.0005 = 2000Hz (2kHz) cycle_time: 0.0005 ; Default beeper tone in kHz. 1 / 0.0005 = 2000Hz (2kHz)
[filament_switch_sensor filament_sensor]
switch_pin: !PA4 # "Pulled-high"
pause_on_runout: True
insert_gcode:
M117 Insert Detected
runout_gcode:
M117 Runout Detected
BEEP i=3 dur=300 freq=400
#*# <---------------------- SAVE_CONFIG ----------------------> #*# <---------------------- SAVE_CONFIG ---------------------->